ISO 13160:2021

Water quality — Strontium 90 and strontium 89 — Test methods using liquid scintillation counting or proportional counting

Water quality — Strontium 90 and strontium 89 — Test methods using liquid scintillation counting or proportional counting

Digital Document2021 edition2021Purchase Options

Referenced standards

ISO 11929-1ISO 3696:1987ISO 80000-10ISO/IEC 17025ISO/IEC Guide 98-3
Unit Price
USD138.06Save 22%
USD 177.00

PREVIEW

ISO 13160:2021

Water quality — Strontium 90 and strontium 89 — Test methods using liquid scintillation counting or proportional counting

Water quality — Strontium 90 and strontium 89 — Test methods using liquid scintillation counting or proportional counting

This document specifies conditions for the determination of 90Sr and 89Sr activity concentration in samples of environmental water using liquid scintillation counting (LSC) or proportional counting (PC).

The method is applicable to test samples of drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample and a chemical separation are required to separate and purify strontium from a test portion of the sample.

The detection limit depends on the sample volume, the instrument used, the sample count time, the background count rate, the detection efficiency and the chemical yield. The method described in this document, using currently available LSC counters, has a detection limit of approximately 10?mBq l-1 and 2?mBq l-1 for 89Sr and 90Sr, respectively, which is lower than the WHO criteria for safe consumption of drinking water (100?Bq·l-1 for 89Sr and 10?Bq·l-1 for 90Sr)[3]. These values can be achieved with a counting time of 1?000?min for a sample volume of 2?l.

The methods described in this document are applicable in the event of an emergency situation. When fallout occurs following a nuclear accident, the contribution of 89Sr to the total amount of radioactive strontium is not negligible. This document provides test methods to determine the activity concentration of 90Sr in presence of 89Sr.

The analysis of 90Sr and 89Sr adsorbed to suspended matter is not covered by this method.

It is the user’s responsibility to ensure the validity of this test method selected for the water samples tested.

Edition2021
Published Date2021
Published ByInternational Standardization Organisation
Page Count41