ISO 13628-5:2009

Petroleum and natural gas industries — Design and operation of subsea production systems — Part 5: Subsea umbilicals

Petroleum and natural gas industries — Design and operation of subsea production systems — Part 5: Subsea umbilicals

Digital Document2009 edition2009Purchase Options

Referenced standards

BS 5099EN 10204:2004IEC 60228IEC 60502-1IEC 60502-2IEC 60793-1-1IEC 60793-2IEC 60794-1-1IEC 60794-1-2ISO 13628-8ISO 1402ISO 4080ISO 4406ISO 4672:1997ISO 6801ISO 6803:2008ISO 7751ISO 8308ITU-T G.976
Unit Price
USD172.38Save 22%
USD 221.00

Petroleum and natural gas industries — Design and operation of subsea production systems — Part 5: Subsea umbilicals

ISO 13628-5:2009 specifies requirements and gives recommendations for the design, material selection, manufacture, design verification, testing, installation and operation of umbilicals and associated ancillary equipment for the petroleum and natural gas industries. Ancillary equipment does not include top side hardware. Topside hardware refers to any hardware that is not permanently attached to the umbilical, above the topside hang-off termination.

ISO 13628-5:2009 applies to umbilicals containing components, such as electrical cables, optical fibres, thermoplastic hoses and metallic tubes, either alone or in combination; and to umbilicals for static or dynamic service, with surface-surface, surface-subsea and subsea-subsea routings .

ISO 13628-5:2009 does not apply to the associated component connectors, unless they affect the performance of the umbilical or that of its ancillary equipment.

ISO 13628-5:2009 applies only to tubes with the following dimensions: wall thickness, t ? 6 mm, internal diameter, ID ? 50,8 mm (2 in). Tubular products greater than these dimensions can be regarded as pipe/linepipe and it is expected that they be designed and manufactured according to a recognised pipeline/linepipe standard.

ISO 13628-5:2009 does not apply to a tube or hose rated lower than 7 MPa (1 015 psi), or to electric cable voltage ratings above standard rated voltages = 3,6/6(7,2) kV rms, where U0, U and Um are as defined in IEC 60502-1 and IEC 60502-2.

Edition2009
Standard Part No5
Published Date2009
Published ByInternational Standardization Organisation
Page Count168