ISO 16422-2:2024

Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 2: Pipes

Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 2: Pipes

Digital Document2024 edition2024Purchase Options

Referenced standards

ISO 1167-1ISO 1167-2ISO 11922-1:1997ISO 12162ISO 161-1ISO 16422-1ISO 16422-5ISO 18373-1ISO 2505ISO 2507-1ISO 3126ISO 3127ISO 4065ISO 4633ISO 6259-2ISO 7686ISO 9080ISO 9852ISO 9969
Unit Price
USD102.96Save 22%
USD 132.00

PREVIEW

ISO 16422-2:2024

Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 2: Pipes

Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 2: Pipes

This document specifies the characteristics of solid-wall pipes made of oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended to be used underground or above-ground (where protected from direct sunlight), for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document.

In conjunction with ISO 16422-1 and ISO 16422-5, this document is applicable to oriented PVC-O pipes, with or without integral socket, intended to be used for the following:

a)?????? water mains and services lines;

b)?????? conveyance of water for both outside and inside buildings;

c)??????? drainage, sewerage and treated wastewater under pressure;

d)?????? irrigation under pressure.

This document is applicable to piping systems intended for the supply of water under pressure up to and including 25?°C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure.

This document is also applicable to components for the conveyance of water and wastewater up to and including 45?°C. For temperatures between 25?°C and 45?°C, see Figure?C.1.

The piping system according to this document is intended for the conveyance of cold water up to pressures of 25?bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25?bar.

[1]? 1?bar = 0,1?MPa = 105 Pa; 1?MPa = 1?N/mm2

Edition2024
Standard Part No2
Published Date2024
Published ByInternational Standardization Organisation
Page Count25