ISO 28765:2016

Vitreous and porcelain enamels — Design of bolted steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges

Vitreous and porcelain enamels — Design of bolted steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges

Digital Document2016 edition2016Purchase Options

Referenced standards

DIN 4119-2:1980EN 10025-1:2004EN 10111:2008EN 10149-1:2013EN 10209:2013EN 15771:2010EN 1991-1-3:2003EN 1991-1-4:2005EN 1991-4:2006EN 1993-1-6:2007EN 1993-4-1:2007EN 1993-4-2:2007EN 1998-1:2004EN 1998-4:2006IISO 15686-1:2011ISO 2178:1982ISO 2746:2015ISO 2859-1:1999ISO 4528:2015ISO 4532:1991ISO 6370-2:2011ISO 8289:2000ISO 9001:2015
Unit Price
USD50.70Save 22%
USD 65.00

PREVIEW

ISO 28765:2016

Vitreous and porcelain enamels — Design of bolted steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges

Vitreous and porcelain enamels — Design of bolted steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges

ISO 28765:2016 establishes the requirements for the design and use of vitreous-enamel-coated bolted cylindrical steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges.

It applies to the design of the tank and any associated roof and gives guidance on the requirements for the design of the foundation.

It applies where

a) the tank is cylindrical and is mounted on a load-bearing base substantially at or above ground level;

b) the product of the tank diameter in metres and the wall height in metres lies within the range 5 to 500;

c) the tank diameter does not exceed 100 m and the total wall height does not exceed 50 m;

d) the stored material has the characteristics of a liquid, exerting a negligible frictional force on the tank wall; the stored material may be undergoing treatment as part of a municipal or industrial effluent treatment process;

e) the internal pressure in the headspace above the liquid does not exceed 50 kPa and the internal partial vacuum above the liquid does not exceed 10 kPa;

f) the walls of the tank are vertical;

g) the floor of the tank is substantially flat at its intersection with the wall; the floor of the tank may have a rise or fall built in to allow complete emptying of the tank contents, the slope of which does not exceed 1:100;

h) there is negligible inertial and impact load due to tank filling;

i) the minimum thickness of the tank shell is 1,5 mm;

j) the material used for the manufacture of the steel sheets is carbon steel (tanks constructed of sheets made from aluminium or stainless steel are outside the scope of this International Standard);

k) the temperature of the tank wall during operation is within the range -50 °C to +100 °C under all operating conditions.

ISO 28765:2016 also gives details of procedures to be followed during installation on site and for inspection and maintenance of the installed tank.

It does not apply to chemical-reaction vessels.

It does not cover resistance to fire.

Edition2016
Published Date2016
Published ByInternational Standardization Organisation
Page Count24