ISO 5910:2018

Cardiovascular implants and extracorporeal systems — Cardiac valve repair devices

Cardiovascular implants and extracorporeal systems — Cardiac valve repair devices

Digital Document2018 edition2018Purchase Options

Referenced standards

ASTM F1830-97IEC 60601-1:2005IEC 62366-1:2015ISO 10555-1:2013ISO 10993-1:2009ISO 10993-2:2006ISO 10993-4:2017ISO 11135:2014ISO 11137-1:2006ISO 11137-2:2013ISO 11137-3:2017ISO 11607-1:2006ISO 11607-2:2006ISO 13485:2016ISO 14155:2011ISO 14160:2011ISO 14630:2012ISO 14937:2009ISO 14971:2007ISO 15223-1:2016ISO 15223-2:2010ISO 17664:2017ISO 5840-1:2015ISO 5840-2:2015ISO 5840-3:2013ISO/IEC 17025:2017ISO/IEC GUIDE 51:2014ISO/TS 11139:2006
Unit Price
USD50.70Save 22%
USD 65.00

PREVIEW

ISO 5910:2018

Cardiovascular implants and extracorporeal systems — Cardiac valve repair devices

Cardiovascular implants and extracorporeal systems — Cardiac valve repair devices

1.1 This document applies to all heart valve repair systems that have an intended use to repair and/or improve the function of native human heart valves by acting either on the valve apparatus or on the adjacent anatomy (e.g. ventricle, coronary sinus).

1.2 This document outlines an approach for verifying/validating the design and manufacture of a heart valve repair system through risk management. The selection of appropriate verification/validation tests and methods are derived from the risk assessment. The tests include assessments of the physical, chemical, biological, and mechanical properties of components and materials of heart valve repair systems. The tests also include preclinical in vivo evaluation and clinical investigation of the finished heart valve repair system to assess the safety and effectiveness of the heart valve repair system.

NOTE For the purposes of this document, effectiveness endpoint includes clinical performance and benefits.

1.3 This document defines operational conditions and performance requirements for heart valve repair systems where adequate scientific and/or clinical evidence exists for their justification.

1.4 This document excludes Cardiac Resynchronization Therapy (CRT) devices, paravalvular leakage closure devices, systems that do not leave an implant in place (e.g. ablation, radio frequency annuloplasty), apical conduits and devices with components containing viable cells. This Standard also excludes materials not intended for repairing and/or improving the function of human heart valves according to its intended use (e.g. patch material and sutures used in general surgical practice).

NOTE A rationale for the provisions of this document is given in Annex A.

Edition2018
Published Date2018
Published ByInternational Standardization Organisation
Page Count126