ISO 80601-2-56:2017

Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement

Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement

Digital Document2017 edition2017Purchase Options

Referenced standards

ASTM E1965-98EN 12470-5:2003IEC 60601-1-11:2015IEC 60601-1-12:2014IEC 60601-1-3:2008IEC 60601-1-9:2007IEC 60601-2-19:2009IEC 62366-1:2015IEC 80601-2-59:2008ISO 14155:2011ISO 14159:2002ISO 14937:2009ISO 15223-1:2016ISO 17664:2004ISO 9000:2015ISO/IEC GUIDE 99:2007
Unit Price
USD138.06Save 22%
USD 177.00

PREVIEW

ISO 80601-2-56:2017

Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement

Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement

ISO 80601-2-56:2017 applies to the basic safety and essential performance of a clinical thermometer in combination with its accessories, hereafter referred to as me equipment. This document specifies the general and technical requirements for electrical clinical thermometers. This document applies to all electrical clinical thermometers that are used for measuring the body temperature of patients.

Clinical thermometers can be equipped with interfaces to accommodate secondary indicators, printing equipment, and other auxiliary equipment to create me systems. This document does not apply to auxiliary equipment.

Me equipment that measures a body temperature is inside the scope of this document.

ISO 80601-2-56:2017 does not specify the requirements for screening thermographs intended to be used for the individual non-invasive human febrile temperature screening of groups of individual humans under indoor environmental conditions, which are given in IEC 80601-2-59[4].

If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.

Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+A1:2012, 7.2.13 and 8.4.1.

NOTE Additional information can be found in IEC 60601?1:2005+A1:2012, 4.2.

Edition2017
Standard Part No58
Published Date2017
Published ByInternational Standardization Organisation
Page Count49