ISO 80601-2-87:2021

Medical electrical equipment — Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators

Medical electrical equipment — Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators

Digital Document2021 edition2021Purchase Options

Referenced standards

IEC 60068-2-27:2008IEC 60068-2-31:2008IEC 60068-2-64:2008IEC 61672-1:2013IEC 62570:2014ISO 14937:2009ISO 16142-1:2016ISO 17664:2017ISO 18562-1:2017ISO 23328-1:2003ISO 23328-2:2002ISO 32:1977ISO 3744:2010ISO 4871:1996ISO 5356-1:2015ISO 5367:2014ISO 7000:2019ISO 7010:2019ISO 7396-1:2016ISO 80369-1:2018ISO 80601-2-55:2018ISO 80601-2-84:2020
Unit Price
USD172.38Save 22%
USD 221.00

PREVIEW

ISO 80601-2-87:2021

Medical electrical equipment — Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators

Medical electrical equipment — Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators

This document applies to the basic safety and essential performance of a high-frequency ventilator (HFV) in combination with its accessories, hereafter referred to as ME?equipment:

  • intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility;

NOTE?1??? For the purposes of this document, such an environment is referred to as a critical care environment. High-frequency ventilators for this environment are considered life-sustaining.

NOTE?2??? For the purposes of this document, such a high-frequency ventilator can provide transport within a professional healthcare facility (i.e., be a transit-operable ventilator).

NOTE?3??? A high-frequency ventilator intended for use in transport within a professional healthcare facility is not considered as a ventilator intended for the emergency medical services environment.

  • intended to be operated by a healthcare professional operator;
  • intended for those patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; and
  • capable of providing more than 150 inflations/min.

There are three principal designations of HFV:

  • high-frequency percussive ventilation [HFPV, with a typical HFV frequency of (60 to 1?000) HFV inflations/min];?
  • high-frequency jet ventilation [HFJV, with a typical HFV frequency of (100 to 1?500) HFV inflations/min]; and
  • high-frequency oscillatory ventilation [HFOV, with a typical HFV frequency of (180 to 1200) HFV inflations/min and typically having an active expiratory phase].?

Additionally, HFV designations can be combined together or with ventilation at rates less than 150?inflations/min.

*?A high-frequency ventilator is not considered a physiologic closed loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings.

This document is also applicable to those accessories intended by their manufacturer to be connected to an HFV breathing system, or to a high-frequency ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the high-frequency ventilator.

If a clause or subclause is specifically intended to be applicable to ME?equipment only, or to ME?systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME?equipment and to ME?systems, as relevant.

Hazards inherent in the intended physiological function of ME?equipment or ME?systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of IEC?60601-1:2005.

NOTE?4??? Additional information can be found in 4.2 of IEC?60601-1:2005+AMD1:2012.

This document is not applicable to ME?equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility.

This document does not specify the requirements for:

  • non-high-frequency ventilators or accessories which provide conventional ventilation for use in critical care environments, which are given in ISO?80601-2-12?[23];.

NOTE?5???? An HFV can incorporate conventional critical care ventilator operational modes, in which case ISO?80601-2-12 is applicable to those modes.

  • ventilators or accessories intended for anaesthetic applications, which are given in ISO?80601-2-13?[24];
  • ventilators or accessories intended for the emergency medical services environment, which are given in ISO?80601-2-84, the replacement for ISO?10651-3?[13];

NOTE?6???? An HFV can incorporate EMS ventilator capability.

  • ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO?80601-2-72?[26];
  • ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO?80601-2-79?[27] and ISO?80601-2-80?[28], the replacements for ISO?10651-6?[15];
  • sleep apnoea breathing therapy ME?equipment, which are given in ISO?80601-2-70?[25];
  • bi-level positive airway pressure (bi-level PAP) ME?equipment;
  • continuous positive airway pressure (CPAP) ME?equipment;
  • respiratory high-flow ME equipment, which are given in ISO 80601-2-90:—1; and
  • cuirass or “iron-lung” ventilation

This document is a particular standard in the IEC?60601 series, the IEC?80601 series and the ISO 80601 series.

?

1 Under preparation. Stage at the time of publication: ISO/DIS?80601-2-90:2020.

Edition2021
Standard Part No89
Published Date2021
Published ByInternational Standardization Organisation
Page Count136