ISO 8100-1:2026

Lifts for the transport of persons and goods Part 1: Safety rules for the construction and installation of passenger and goods passenger lifts (Edition 2, 2026)

Lifts for the transport of persons and goods Part 1: Safety rules for the construction and installation of passenger and goods passenger lifts (Edition 2, 2026)

Digital Document2026Purchase Options

Referenced standards

EN 13411-3:2022EN 13411-6:2004+A1:2008EN 13411-7:2021EN 13411-8:2011EN 13501-1:2018EN 13501-6:2018+A1:2022EN 50214:2024EN 81-28:2022IEC 60227-6:2001IEC 60332-1-2:2025IEC 60364-6:2016IEC 60598-1:2024IEC 60664-1:2020IEC 60947-4-1:2023IEC 60947-5-1:2024IEC 61310-3:2007IEC 61508-1:2010IEC 61800-5-2:2016IEC 61810-3:2015ISO 12100:2010ISO 1219-1:2012ISO 12543-2:2021ISO 12543-3:2021ISO 13857:2019ISO 14122-2:2016ISO 14122-3:2016ISO 14122-4:2016ISO 29584:2015ISO 4190-5:2006ISO 4344:2022ISO 4413:2010ISO 6743-4:2015ISO 7000:2019ISO 7010:2019ISO 8100-2:2026ISO 8100-33:2022ISO 8102-1:2020ISO 8102-20:2022ISO 8102-2:2021
Unit Price
USD227.00Save 21%
USD 287.61

PREVIEW

ISO 8100-1:2026

Lifts for the transport of persons and goods Part 1: Safety rules for the construction and installation of passenger and goods passenger lifts (Edition 2, 2026)

Lifts for the transport of persons and goods Part 1: Safety rules for the construction and installation of passenger and goods passenger lifts (Edition 2, 2026)

Abstract

This document specifies the safety rules for lifts permanently serving buildings and constructions and intended for the transport of persons or persons and goods. It applies to traction lifts, positive drive lifts and hydraulic lifts that:

serve specific levels; and

have a rated speed exceeding 0,15 m/s; and

have an enclosed car; and

move along guide rails inclined not more than 15° to the vertical; and

   are indoor or weather-protecte

This document also applies to the electrical equipment of these lifts including the lighting and socket outlets in the well.

This document specifies safety rules related to:

persons to be safeguarded:

users, including passengers, maintenance and inspection personnel;

persons at the landings and outside of the well, or any machinery space and pulley room, who can be affected by the lift.

property to be safeguarded:

loads in the car;

components of the lift installation;

building in which the lift is installed.

This document does not specify additional requirements for:

lifts serving buildings with requirements for seismic conditions;

lifts serving buildings with requirements for accessibility;

lifts exposed to vandalism;

lifts which can be used for firefighting and evacuation purposes under firefighters control;

lifts which can be used to support faster evacuation of persons with disabilities;

the behaviour of the lift when the control system of the lift receives a recall signal(s) in the event of fire in a building.

This document is not applicable to passenger and goods passenger lifts, which are installed before the date of its publication.

General information